Air Systems The Breather Box™
:: Specifications
- Filter change Indicators
- Incoming Air Plug 1/2" Industrial Interchange
- 2 Automatic Drains with Discharge tubes
- 3 standard Power Options
- Specify Respirator couplings
- Carbon monoxide monitor standard
- CO/O2 monitor Available
- Intrinsically safe Versions Available
- Remote Alarm Receptacle
- External warning Lights and Alarm
- Safety Relief Valve
- Visual Air Flowmeter to monitor
- Airline Monitor Specifications: Calibration: Less than 2 minutes
- Monitor display: LCD 3-digit readout
- Temperature range: 4°F to 113°F (-20°C to 45°C)
- Accuracy: +/- 1% of full scale
- Monitor range: Carbon Monoxide (CO) 0-200 ppm, Oxygen (O2) optional 15-23%
- Pressure range: 1-3 psi, flow 50-100 cc
- Response: 90% of full scale in 10 seconds
- Sensor type: 3-electrode electrochemical with bias voltage
- Humidity range: 5% to 95% relative humidity
- Warranty: 2 years on entire unit and CO sensor (1 year on oxygen sensor)
- Alarm set point: 10 ppm CO (5 ppm Canada); 19.5% O2 option
- Voltage operation: 115 VAC, dual 9 VDC battery, or 8-16 VDC, 230 VAC optional
- Shielding: Internal RFI/EMI circuitry, aluminum case
- Test circuitry: Manual push-to-test for sensor operation and alarms
- Warning indicators: Low battery (amber), normal operation (green), high CO (red), low O2 option (red). LED locations may vary with model ordered.
- Output signals (standard): DC output on portables, AC output on panel versions
- Monitor housing: Black anodized aluminum
- Control panel standard features: Inlet gas quick connect coupling, auxiliary 12 VDC jack, on/off/test switch, auxiliary/remote alarm jack, 115 VAC jack
- CO or CO/O2 monitors available with intrinsically safe (IS) certification
- Panel Mounted CO Monitors Specifications: Visual Air Flowmeter to monitor
- Carbon monoxide monitor standard
- CO/O2 monitor Available
- Intrinsically safe Versions Available
- Audible and Visual Alarms
- 115 VAc Remote Alarm connections
- 115 VAc Power cord
- 230 VAc Optional
- The Breather Box Models, Standard Models - CO Monitoring: BB15-CO Breather Box™ - 15 cfm (24 cfm flow capacity), 1 coupling
- BB30-CO Breather Box™ - 30 cfm (48 cfm flow capacity), 2 couplings
- BB30-CO3 Breather Box™ - 30 cfm (48 cfm flow capacity), 3 couplings
- BB50-CO Breather Box™ - 50 cfm (79 cfm flow capacity), 4 couplings
- BB75-CO Breather Box™ - 75 cfm (97 cfm flow capacity), 6 couplings
- BB100-CO Breather Box™ - 100 cfm (123 cfm flow capacity), 4 couplings
- BB100-CO6 Breather Box™ - 100 cfm (123 cfm flow capacity), 6 couplings
- BB100-CO8 Breather Box™ - 100 cfm (123 cfm flow capacity), 8 couplings
- BB150-CO Breather Box™ - 150 cfm (203 cfm flow capacity), 3 each x 1/2"
- Carbon Monoxide & Oxygen Monitoring: BB30-COO2 Breather Box™ filtration system supplied with a dual CO and O2 monitor - 30 cfm (48 cfm flow capacity), 2 couplings
- BB50-COO2 Breather Box™ filtration system supplied with a dual CO and O2 monitor - 50 cfm (79 cfm flow capacity), 4 couplings
- BB100-COO2 Breather Box™ filtration system supplied with a dual CO and O2 monitor - 100 cfm (123 cfm flow capacity), 4 couplings
- Independent Regulators: BB30-CO2R Breather Box™ filtration system with CO monitor, supplied with 2 independent regulators - 30 cfm (48 cfm flow capacity), 2 couplings
- BB50-CO4R Breather Box™ filtration system with CO monitor, supplied with 4 independent regulators - 50 cfm (79 cfm flow capacity), 4 couplings
- BB100-CO4R Breather Box™ filtration system with CO monitor, supplied with 4 independent regulators - 100 cfm (123 cfm flow capacity), 4 couplings
- Intrinsically Safe - CSA Approved: BB15-COIS Intrinsically safe Breather Box™ filtration system supplied with 9-VDC only CO monitor - 15 cfm (24 cfm flow capacity), 1 couplings
- BB30-COIS Intrinsically safe Breather Box™ filtration system supplied with 9-VDC only CO monitor - 30 cfm (48 cfm flow capacity), 2 couplings
- BB50-COIS Intrinsically safe Breather Box™ filtration system supplied with 9-VDC only CO monitor - 50 cfm (79 cfm flow capacity), 4 couplings
- BB100-COIS Intrinsically safe Breather Box™ filtration system supplied with 9-VDC only CO monitor - 100 cfm (123 cfm flow capacity), 4 couplings
- CO Monitor Panels: CO-91PM Panel mounted CO monitor, 9 VDC and/or 115 VAC, audible alarm, visual lights, flowmeter, quick connect calibration fitting, LCD display
- CO-91PMIS Panel mounted intrinsically safe CO monitor, 9 VDC only, audible alarm, visual lights, flowmeter, quick connect calibration fitting, LCD display - CSA Approved
- CO2-91PM Panel mounted Carbon Monoxide and Oxygen airline monitor simultaneously monitors for high CO and low O2, 9 VDC and/or 115 VAC, audible alarm, visual lights, flowmeter, quick connect calibration fitting, LCD display
- Airline Monitor:CO-91 CARBON MONOXIDE AIRLINE MONITOR REPLACEMENT FOR MONITOR IN BREATHER BOX
- CO-91IS INTRINSICALLY SAFE CO MONITOR-9V ONLY, REPLACEMENT FOR BB SERIES IS BR.BOX
- CO2-91 CARBON MONOXIDE AND OXYGEN MONITOR, REPLACEMENT FOR BB50-COO2 SERIES
- Replacement Breather Box™ and Panel Filters
- BB15 & BB30 Series Breather BoxTM Models: BB30-A Replacement particulate filter - 30 cfm, Stage 1
- BB30-C Replacement coalescing filter - 30 cfm, Stage 2
- BB30-D Replacement charcoal filter - 30 cfm, Stage 3
- BB30-FK Filter kit for BB30-CO series Breather BoxTM models, Contains 1 ea. "A", "C", and "D" replacement filters
- BB50 Series Breather BoxTM Models: BB50-A Replacement particulate filter - 50 cfm, Stage 1
- BB50-C Replacement coalescing filter - 50 cfm, Stage 2
- BB50-D Replacement charcoal filter - 50 cfm, Stage 3
- BB50-FK Filter kit for BB50-CO series Breather BoxTM models, Contains 1 ea. "A", "C", and "D" replacement filters
- BB75 Series Breather BoxTM Models: BB75-A Replacement particulate filter - 75 cfm, Stage 1
- BB75-C Replacement coalescing filter - 75 cfm, Stage 2
- BB75-D Replacement charcoal filter - 75 cfm, Stage 3
- BB75-FK Filter kit for BB75-CO series Breather BoxTM models, Contains 1 ea. "A", "C", and "D" replacement filters
- BB100 & BB150 Series Breather BoxTM Models: BB100-A Replacement particulate filter - 100 cfm, Stage 1 50.00 A
- BB100-C Replacement coalescing filter - 100 cfm, Stage 2 155.00 A
- BB100-D Replacement charcoal filter - 100 cfm, Stage 3 165.00 A
- BB100-FK Filter kit for BB100-CO series Breather BoxTM models, Contains 1 ea. "A", "C", and "D" replacement filters
- Replacement Sensors for Air Systems' Airline Monitors: CO-91NS New CO sensor for CO-91 series monitors (2 year warranty)
- CO2-O2 New Oxygen sensor for CO2-91 series monitors (1 year warranty)
- Airline Monitor Calibration Kits Small Calibration Kits 17 Liter Cylinder Size (disposable): BBK-20 Calibration Kit for CO monitors, 20 ppm CO gas, zero air, preset regulator, tubing and case
- BBK-10 Calibration Kit for Canadian CO monitors, 10 ppm CO gas, zero air, preset regulator, tubing and case
- Large Calibration Kits 103 Liter Cylinder Size (disposable): BBK-20103 Calibration Kit for CO monitors, 20 ppm CO gas, zero air, preset regulator, tubing and case
- BBK-10103 Calibration Kit for Canadian CO monitor, 10 ppm CO gas, zero air, preset regulator, tubing and case
- Calibration Gas and Accessories: BBG-00 Replacement Calibration gas, zero air, 17 liter
- BBG-10 Replacement Calibration gas for Canadian CO requirements, 10 ppm CO for BBK-10 kit, 17 liter
- BBG-20 Replacement Calibration gas, 20 ppm CO, 17 liter
- BBG-02 Oxygen sensor test gas, 20.9% in nitrogen, 17 liter
- BBK-R17 Calibration regulator for 17 liter cylinders, preset flow 300cc
- BBG-00103 Replacement Calibration gas, zero air, 103 liter
- BBG-10103 Replacement Calibration gas for Canadian CO requirements, 10 ppm CO for BBK-10103 kit, 103 liter
- BBG-02103 Oxygen sensor test gas, 20.9% oxygen in nitrogen, 103 liter
- BBG-20103 Replacement Calibration gas, 20 ppm CO, 103 liter
- BBK-R103 Calibration regulator and gauge for 103 liter cylinders, preset flow 300cc
:: Features
- The Breather Box™ High Performance Portable Grade-D Breathing Air Filtration System
- Provide respirator users with Grade-D quality air and monitors for CO and/or Oxygen.
- Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes™ are designed to be used in the upright and closed position to prevent internal contamination