Product: Qty:

Auto-Air™:

Questions? | Quote | Email

Checkout

What is an Auto-Air System? If IDLH work environments exist, the the Auto-Air™ Breather Box™ option should be considered. The Auto-Air™ filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs a 60psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system. The Auto-Air™ feature is offered in electric or pneumatic versions. Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder. For technical questions, contact Air Systems' Customer Service Department.

  • the Auto-Air™ Breather Box™ Fully Automatic Reserve Air system for work in IDLH environments
  • The primary air line connection is attached from the compressor to the Auto-Air™ Breather Box™. A reserve air line is attached from a single or bank of air cylinders based on the required egress duration. The system can be tested prior to each use to ensure proper function of the Auto-Air™ system.

  • Air Systems Auto-Air Breather Box

    Air Systems Auto-Air™ Breather Box™

    :: Specifications

    • Primary Air Line, ½" Inlet Fitting
    • Reserve Air Line, ¼" Inlet Fitting
    • Filter change Indicators
    • 2 Automatic Drains with Discharge tubes
    • Ac Power Receptacle
    • Carbon monoxide monitor standard
    • CO/O2 monitor Available
    • Intrinsically safe Pneumatic Versions Available
    • Remote Alarm Receptacle
    • External warning Lights and Alarm
    • Safety Relief Valve
    • Specify Respirator couplings
    • Visual Air Flowmeter to monitor
    • Auto-Air™ Breather Box™ Pricing includes 1/4" Hansen style or Schrader style fittings. Specify when ordering. Optional fittings are available for an additional charge.
    • Standard electric Models: BB30-COAA Auto-AirTM Breather Box™ filtration system - 30 cfm (48 cfm flow capacity), 2 couplings, 115 VAC required, order reserve air cylinders and connect hose separately
    • BB50-COAA Auto-AirTM Breather Box™ filtration system - 50 cfm (79 cfm flow capacity), 4 couplings, 115 VAC required order reserve air cylinders and connect hose separately
    • BB100-COAA Auto-AirTM Breather Box™ filtration system - 100 cfm (123 cfm flow capacity), 4 couplings, 115 VAC required order reserve air cylinders and connect hose separately
    • Intrinsically Safe Models - Approved Monitor: BB30-COAAP Auto-AirTM Breather Box™ filtration system - 30 cfm (48 cfm flow capacity), 2 couplings, 9-volt DC only, order reserve air cylinders and connect hose separately
    • BB50-COAAP Auto-AirTM Breather Box™ filtration system - 50 cfm (79 cfm flow capacity), 4 couplings, 9-volt DC only, order reserve air cylinders and connect hose separately
    • BB100COAAP Auto-AirTM Breather Box™ filtration system - 100 cfm (123 cfm flow capacity), 4 couplings, 9-volt DC only, order reserve air cylinders and connect hose separately
    • Replacement Filters: BB15 & BB30 Series Breather BoxTM Models: BB30-A Replacement particulate filter - 30 cfm, Stage 1
    • BB30-C Replacement coalescing filter - 30 cfm, Stage 2
    • BB30-D Replacement charcoal filter - 30 cfm, Stage 3
    • BB30-FK Filter kit for BB30-CO series Breather BoxTM models Contains 1 ea. "A", "C", and "D" replacement filters
    • BB50 Series Breather BoxTM Models: BB50-A Replacement particulate filter - 50 cfm, Stage 1
    • BB50-C Replacement coalescing filter - 50 cfm, Stage 2
    • BB50-D Replacement charcoal filter - 50 cfm, Stage 3
    • BB50-FK Filter kit for BB50-CO series Breather BoxTM models Contains 1 ea. "A", "C", and "D" replacement filters
    • BB75 Series Breather BoxTM Models: BB75-A Replacement particulate filter - 75 cfm, Stage 1
    • BB75-C Replacement coalescing filter - 75 cfm, Stage 2
    • BB75-D Replacement charcoal filter - 75 cfm, Stage 3
    • BB75-FK Filter kit for BB75-CO series Breather BoxTM models Contains 1 ea. "A", "C", and "D" replacement filters
    • BB100 & BB150 Series Breather BoxTM Models: BB100-A Replacement particulate filter - 100 cfm, Stage 1
    • BB100-C Replacement coalescing filter - 100 cfm, Stage 2
    • BB100-D Replacement charcoal filter - 100 cfm, Stage 3
    • BB100-FK Filter kit for BB100-CO series Breather BoxTM models Contains 1 ea. "A", "C", and "D" replacement filters
    • Replacement Sensors for Air Systems' Airline Monitors: CO-91NS New CO sensor for CO-91 series monitors (2 year warranty)
    • CO2-O2 New Oxygen sensor for CO2-91 series monitors (1 year warranty)
    • Airline Monitor Calibration Kits Small Calibration Kits 17 Liter Cylinder Size (disposable): BBK-20 Calibration Kit for CO monitors, 20 ppm CO gas, zero air, preset regulator, tubing and case
    • BBK-10 Calibration Kit for Canadian CO monitors, 10 ppm CO gas, zero air, preset regulator, tubing and case
    • Large Calibration Kits 103 Liter Cylinder Size (disposable): BBK-20103 Calibration Kit for CO monitors, 20 ppm CO gas, zero air, preset regulator, tubing and case
    • BBK-10103 Calibration Kit for Canadian CO monitor, 10 ppm CO gas, zero air, preset regulator, tubing and case
    • Calibration Gas and Accessories: BBG-00 Replacement Calibration gas, zero air, 17 liter
    • BBG-10 Replacement Calibration gas for Canadian CO requirements, 10 ppm CO for BBK-10 kit, 17 liter
    • BBG-20 Replacement Calibration gas, 20 ppm CO, 17 liter
    • BBG-02 Oxygen sensor test gas, 20.9% in nitrogen, 17 liter
    • BBK-R17 Calibration regulator for 17 liter cylinders, preset flow 300cc
    • BBG-00103 Replacement Calibration gas, zero air, 103 liter
    • BBG-10103 Replacement Calibration gas for Canadian CO requirements, 10 ppm CO for BBK-10103 kit, 103 liter
    • BBG-02103 Oxygen sensor test gas, 20.9% oxygen in nitrogen, 103 liter
    • BBG-20103 Replacement Calibration gas, 20 ppm CO, 103 liter
    • BBK-R103 Calibration regulator and gauge for 103 liter cylinders, preset flow 300cc

    :: Features

    • Did You Know? NIOSH requires the use of 5 minute airline escape respirators when working in IDLH environments. Our Auto-Air™ feature does not replace the NIOSH requirement, however, some work environments may require a 30 minute or longer airline escape method to safely egress the hazardous area. This situation would require the use of an Auto-Air Breather Box™ or Cart.

    Sponsored Links:

    Font Size: Decrease Font SizeIncrease Font Size Switch views: Normal View Printer-Friendly View What's this?